Katarakt Cerrahisi Öncesi Honan Balonu Uygulaması

H.İbrahim İMAMOĞLU*, Hidayet ERDÖL**
*Yard.Doç.Dr. KTÜ Tıp Fak. Göz Hast. ABD,** Dr. KTÜ Tıp Fak. Göz Hast. ABD, TRABZON



HONAN INTRAOCULAR PRESSURE REDUCER PRECEDING CATARACT SURGERY
15 of patients scheduled for cataract surgery were applied external compression with the Honan intraocular pressure
(IOP) reducer. The others were taken as a control group. The avarage increase in IOP of whole patients after retrobulbar
enjection was 7.37 mmHg. In the first 2 1/2 minutes. IOP was found averaging 0,80 mmHg below baseline level for the
Honan group and 0.18 mmHg above baseline level for the control group. From 5 to 15 minutes after injection there was a
more gradual decline In IOP in the Honan group while there was no significant difference in IOP in the control grou. In 15
minutes, the IOP was 6.53 mmHg below baseline level in Honan group. Between the IOP measurements of the two
groups there was no statistical difference (P>0.01) at 2 1/2 minutes while a marked statistical difference was seen
(P<0.01) at 5.10 and 15 minutes.


Keywords: intraocular pressure, Honan IOP reducer, Cataract surgery

E-mail To Friend This Page Printer Friendly Page
 
 
 ARAMA
  
 Ayrıntılı Arama
 GİRİŞ
 Kullanıcı Adı :
 
 Şifre  
   Beni Hatırla
 Şifremi Unuttum
 Kayıt Ol
 
 
 
 
 
 
 
 

Yasal uyarı: Bu sitede yayınlanan resim, yazı ve diğer uygulamaların her hakkı Ortadoğu Reklam Ve Yayıncılık A.Ş. 'ye aittir. Kaynak gösterilmeden kullanılamaz. Bu site hekimleri sağlık alanında bilgilendirmeye yönelik hazırlanmıştır. Sitede yer alan bilgiler tanı ve tedavi amaçlı kullanıldığında sorumluluk tamamen kullanıcıya aittir. Siteye girmekle bu şartları okumuş, anlamış ve kabul etmiş sayılırsınız.