Dilaver ERŞANLI*, Yusuf ÖZERTÜRK**
* Yrd. Doç. Dr. GATA Haydarpaşa Eğitim Hastanesi Göz Kliniği, Doç Dr. Acıbadem Cad. Nişantaşı Durak Alsancak Sitesi 1. Blok D.24 Kadıköy/ İSTANBUL



Managing the implantation of PC.IOL. with scleral fixation more practically and less cost effective was aimed in this study.
The PC.IOL. with transskleral fixation was implanted to be used 27 gauge handled straight needle whose bevel with a hole and by using 9/10 polyproplene suture to eleven patients with ages ranged from 4 to 65 years, 4 of which were women, 7 were men.
Of 11 patients , in two minimum hemorrhages occured into vitreous. In one case the cut suture happened.
It was concluded that both PC.IOL. implantation with scleral fixation and dislocated IOL can successfully be treated more practically and less expenses with a 27 gauge needle that has a hole in the bevel loaded with the suture.


Keywords: Transskleral IOL fixation, 27 gauge handled straight needle that has a hole in the bevel

Turkiye Klinikleri Oftalmoloji 1997, 6:140-142

E-mail To Friend This Page Printer Friendly Page
 
 
 ARAMA
  
 Ayrıntılı Arama
 GİRİŞ
 Kullanıcı Adı :
 
 Şifre  
   Beni Hatırla
 Şifremi Unuttum
 Kayıt Ol
 
 
 
 
 
 
 
 

Yasal uyarı: Bu sitede yayınlanan resim, yazı ve diğer uygulamaların her hakkı Ortadoğu Reklam Ve Yayıncılık A.Ş. 'ye aittir. Kaynak gösterilmeden kullanılamaz. Bu site hekimleri sağlık alanında bilgilendirmeye yönelik hazırlanmıştır. Sitede yer alan bilgiler tanı ve tedavi amaçlı kullanıldığında sorumluluk tamamen kullanıcıya aittir. Siteye girmekle bu şartları okumuş, anlamış ve kabul etmiş sayılırsınız.