04-12-2008

Dergi Hakkında
Yayın Kurulu
Danışma Kurulu
Yazım Kuralları
Yayın Hakları Devir Formu
Online Makale İşlemleri
İletişim
Oftalmoloji Dergisi
ISSN: 1300-0365
Dil: Türkçe

 

ORIGINAL RESEARCH ARTICLES


The Assessment Of Automated Perimetry, Contrast Sensitivity, Central Corneal Thickness And Farnsworth-munsell 100 Hue Test Results In Ocular Hypertension

Dr. Abdullah KARACA,a Dr. Üzeyir GÜNENÇ,a Dr. Zeynep ÖZBEK,a Dr. Güray ÇINGIL,a Dr. Mehmet H. ERGİNa
aGöz Hastalıkları AD, Dokuz Eylül Üniversitesi Tıp Fakültesi, İZMİR



Objective: To evaluate the results of automated perimetry, central corneal thickness (CCT), contrast sensitivity and Farnsworth-Munsell 100 Hue test in Ocular Hypertension (OHT) and compare these results with those of normal population.
Material and Methods: Twenty-five patients examined at Department of Ophthalmology, Dokuz Eylul University School of Medicine between January 1999 and April 2003 and diagnosed to have OHT and 25 healthy volunteers were included in the study. After a thorough ophthalmologic examination, Humphrey blue-on-yellow (B-Y) and white-white (W-W) perimetry were performed to both the study and control groups at the initial visit. After eighteen months , two groups were compared by means of Humphrey automated perimetry, CCT, contrast sensitivity and Farnsworth-Munsell 100 Hue colour test results.
Results: At the initial visit, B-Y perimetry parameters were as follows in OHT group: Mean Deviation (MD):-2.93±0,62, Pattern Standard Deviation (PSD):3.48±0,88, Short Time Fluctation (SF):2.94±0.76. The W-W perimetry parameters of the same group were as follows; MD:-1.44±0.50, PSD:2.06±0,81, SF:1.9±0.62. In the control group B-Y perimetry parameters were; MD:-3.61±0.54, PSD:3.72±0.71, SF:2.4±0.43, W-W perimetry parameters were MD:-1.68±0.48, PSD:2.0±0.74, SF:1.84±0.42. Two patients were excluded from the OHT group since they underwent glaucomatous progression. After eighteen months, in OHT group, B-Y perimetry, parameters were MD:?4.95±0.72, PSD: 3.72±0.53, SF:2.34±0.41. W-W perimetry results were; MD:-1.63±0.37, PSD:2.14±0.57, SF:2.86±0.63. In the control group B-Y perimetry parameters were; MD: -4.81±0.56, PSD: 3,94±0.45, SF:2.6±0.51, and W-W perimetry parameters were; MD:-1.66±0.32, PSD: 2.21±0.44, SF:1.78±0.26. No statistically significant difference could be detected between the groups except MD results in B-Y perimetry (p>0.05). In addition to perimetry, two groups were evaluated with CCT (Orbscan II), contrast sensitivity (VCI Vision Contrast Test System) and with Farnworth Munsell 100 Hue colour test. No statistically signicificant difference could be detected between the two groups with regard to CCT (568±23,3 µm in OHT group, 526±26,2 µm in control group) and contrast sensivity despite lower contrast sensitivities in all spatial frequencies in OHT group. In Farnsworth Munsell 100 Hue test, no difference was present at red-green axis, but Total Error Scors (TES) and Blue-Yellow Axis (BYA) error scors were significantly higher in OHT group.
Conclusion: MD parameter of the B-Y perimetry seems to be more sensitive for the follow up of OHT. Although higher BYA error scores and lower contrast sensitivity levels are detected in the OHT group, more studies are needed to decide the predictive values of these tests.


Keywords: Contrast Sensitivity , blue on yellow perimetry, ocular hypertension , 100 hue test

Turkiye Klinikleri J Ophthalmol 2004, 13:185-192

E-mail To Friend This Page Printer Friendly Page
 
 
 ARAMA
  
 Ayrıntılı Arama
 GİRİŞ
 Kullanıcı Adı :
 
 Şifre  
   Beni Hatırla
 Şifremi Unuttum
 Kayıt Ol
 
 
 
 
 
 
 
 

Yasal uyarı: Bu sitede yayınlanan resim, yazı ve diğer uygulamaların her hakkı Ortadoğu Reklam Ve Yayıncılık A.Ş. 'ye aittir. Kaynak gösterilmeden kullanılamaz. Bu site hekimleri sağlık alanında bilgilendirmeye yönelik hazırlanmıştır. Sitede yer alan bilgiler tanı ve tedavi amaçlı kullanıldığında sorumluluk tamamen kullanıcıya aittir. Siteye girmekle bu şartları okumuş, anlamış ve kabul etmiş sayılırsınız.